Guideline Acceptance Criteria for Platform Inspection
I. Above Water and Splash Zone Visual and Coating Survey
- Jacket Structure
- Deck Structure
- Appurtenance and Personnal Safety Device Survey
- Equpment Survey
API RP 2 SIM
Par. 6.3.1
...
Indications of obvious overloading, deteriorating coating systems, excessive
corrosion, and bent, missing, or damaged members of the structure in the splash
zone and above water. Guidance on the grading of coating systems is provided in
NACE SP0108.
Damage or
deterioration to appurtenances and personnel safety, escape, and evacuation
devices.
Baca Juga ► Procedure Platform Inspection
API RP 2 SIM Par. 6.3.2
...Components should be inspected for presence of damage, straightness, corrosion, weld integrity, and modifications. If above-water damage is detected, a complete record of the damage should be made with sufficient detail to allow engineering personnel to determine if repairs or further NDT are required. ...
API RP 2 SIM Par 6.3.3
The Level I survey should include a coating survey to assess the effectiveness and condition of the various protective coating systems on the topsides. The inspection should detect deteriorating coating systems and excessive corrosion.